  • Din sized enclosure for panel / Track / Screw mounting.
  • Front terminal protective cover for safety.
  • Knob lock to protect from unintentional change of time setting.
  • LED indication for timing in progress.
  • Large transparent knob for precise time setting.
  • Accepts any voltage from 12 VAC/DC to 220VAC/DC as
        signal  between command contacts for timing initiation.
  • Dimensions:
         1.  48 X 48 X 94.5mm(W x H x D) (Screw Type)
         2.  48 X 48 X 94mm ( W x H x D) (Plug-in Type)

Product Ranges

Electronic Timers

                           A-Series

                           B-Series

                           Digital Timers

                           H-Series

                           S-Series

Monitoring Devices


Power Supplies


Annunciators

Energy Management System

Tachometers

Time Switch


Hour Meters

Counters

Unik Temp
                          TX7 Series

                           H3TX Series

                           EX-9 Series

_______________________________

H series

H1DA-X
Accepts any voltage from 12V AC/ DC to 240V AC / 220V DC as signal between command contacts for timing initiation

H1D1-X / H3D1
Multifunction timer Ondelay/Interval/ equal ON / OFF, equal OFF / ON
Model
Function
Source Voltage
Time Range
Specifications
Operating Instructions
H3D1

Multi function timer (8terminals) Screw Type

 X-Version
0.3Secs to 60Mins
H1D1-X
Multi-function timer (11 Pin) plug in type
X-Version
0.3 Secs to 60Mins
H1DA-X
Signal OFF delay timer (11 Pin) plug in type
    X-Version
0.6 Secs to 60Mins
H1DT-10
ON Delay(11Pin) plug in type
X-Version
1 Secs to 10 Secs
H1DT-30
ON Delay(11Pin) plug in type
X-Version
3 Secs to 30 Secs
H1DT-60
ON Delay(11Pin) plug in type
X-Version
6 Secs to 60 Secs
H4DT-10
ON Delay(8pin) plug in type
X-Version
1 Sec to 10 Secs
H4DT-30
ON Delay(8pin) plug in type
X-Version
3 Secs to 30 Secs
H4DT-60
ON Delay(8pin) plug in type
X-Version
6 Secs to 60 Secs
**X-Version:24VAC/DC to 240VAC/220VDC
Design & Specifications are subject to change without notice.
Our Recommendation on Relay Operation is One LAKH. However, if the operations crossed two LAKH We recommend replacing the unit to avoid inadvarent stoppage.
User is recommended to confirm the suitability of EAPL product range for intended application.
EAPL is not responsible for consequential damage arising out of use of its products.
Note : If you do not get the required model with any dealer for what so ever reason,kindly
Contact Us immediately for  helping you out.