Features

  • Auto / Manual reset facility.
  • Relay contact for Tripping
  • PMD - 01: 1. Din sized enclosure for screw / track.
                            2. Dimension:45 x 75 X116mm (W x H x D).
  • PVMD & PVIMD: 1. Din sized enclosure for Panel mounting.
                                  2. Trip Delay time can be selected individually for
                                      each parameter.
                                  3. Unwanted parameter can be bypassed.
                                  4. LED indication for relay status.
                                  5. Type of fault display whenever fault
                           occurs.

                                  6. Dimension:96 x96 X112mm (W x H x D)

Product Ranges

Electronic Timers

                           A-Series

                           B-Series

                           Digital Timers

                           H-Series

                           S-Series

Monitoring Devices


Power Supplies


Annunciators

Energy Management System

Tachometers

Time Switch


Hour Meters

Counters

Unik Temp
                          TX7 Series

                           H3TX Series

                           EX-9 Series

_______________________________

 

Monitoring Devices

PMD-01
Monitors phase sequence, phase failure, phase unbalance & under voltage in a 3 phase system & trips under such condition
LED indication for power, relay status and fault condition
All parameter factory set.
Manual reset button on front panel
PVMD/PVIMD /PVMD-G/PVIMD-G

Monitors phase sequence, phase failure, phase unbalance, over voltage & under voltage in a 3 phase system & trip under such condition (PVMD & PVMD-G). In case of PVIMD & PVIMD-G, in addition to the above features, it also has under, over current and Inrush time.
Digital display of voltage in PVMD & PVMD-G, voltage & current in PVIMD & PVIMD-G under normal condition.
Under and over voltage settings done based on nominal voltage which also can be set.
Under and over current settings done based on nominal voltage which also can be set(PVIMD & PVIMD-G).

Terminals provided for external CT connection, programmable upto 500 CT primary and CT-Secondary by default-5. (PVIMD & PVIMD-G)

PVMD-G \ PVIMD-G Mounting: Dinrail\ srew PVMD\PVIMD: Mounting\panel\flush
Model
Function
Source Voltage
Output
Specifications
Operating Instructions
PMD-01
Phase Monitoring Device
440V AC, 3 phase 3 wire
1 c/o relay*
PVMD
Phase and Voltage Monitoring Device
3 Phase 4 wire
1 relay c/o
PVIMD
Phase , Voltage and Current Monitoring Device
   3 phase 4 wire
1 relay c/o
PVMD-G
Phase and Voltage Monitoring Device
3 Phase 4 wire
1 relay c/o
PVIMD-G
Phase , Voltage and Current Monitoring Device
   3 phase 4 wire
1 relay c/o
* PMD-01 with 2 relay c/o onrequest for bulk quantity .
Design & Specifications are subject to change without notice.
User is recommended to confirm the suitability of EAPL product range for intended application.
EAPL is not responsible for consequential damage arising out of use of its products.