Model :A1DA |
|
| Rated supply voltage | 240V AC/ 110V AC |
| Operating Voltage Range | -20% to +10% of the rated voltage. |
| Rated Frequency | 50 Hz ±5% |
| Control Output | 1C/O rated for 5A @ 250V AC / 28V DC resistive load. |
| Setting Accuracy | ±10%max. w.r.t full scale ±100mSec |
| Repeat Accuracy | ±1% max. ±100mSec |
| Recovery Time | 100mSec minimum |
| Rated Frequency of operation | 1800 ±5% operations per hour max |
| Variation due to voltage change | ±2%max ±100mSec |
| Variation due to temp.change | ±5%max. ±100mSec |
| Variation due to frequency change | ±2%max. ±100mSec |
| Ambient temperature | Operation:-10 to +55° C Storage: -25 to +80° C |
| Humidity | Max 85% RH @40° C |
| Service Life | 106 operations minimum(under no load) |
| Electrical Life | 105 operations minimum(under full load) |
| Electric Connections | Screw type terminals with self lifting clamps |
| Dimensions | 22.5 X 75 X 102mm (W X H X D) |
| Power Consumption | AC approx. 10VA/2W |
| Insulation Resistance | >100M ohms @ 500V DC |
| Range Selection | 3 Sec,30 Sec,3Min,30Min |
| Dielectric Strength | 01)2.5KV AC,50Hz for 1 Minute.(between current carrying & non-current carrying parts) 02)1.5KV AC,50Hz for 1 Minute.(between contacts & control circuit) 03)1KV AC ,50Hz for 1 Minute.(between non-continuous relay contacts) |
| Start Signal | Potential free closure for a minimum of 150 msecs |
| Time Range | 0.3 Sec to 30Min |
| Enclosure(series) | A1D series |
ISSUE DATE:For 240V AC:15/07/04