Model : TX7-2H-U
Function
2 Set point temp. Controller(Heater type)
Rated Supply Voltage
85V to 270V AC/DC
Rated Frequency
50/60 Hz ±5% for AC only
Power consumption
AC Aprox. 4VA / 1W
Control Output

1 c/o contact rated for 5A@250V AC / 28V DC resistive load for each set point.

Display accuracy

±(0.5% of full scale)±10 C  

Hysterisis
20 C -200 C
Range
00 C - 6000 C (J TYPE)
00 C - 12000 C (K TYPE)
00 C - 3000 C (PT100) 
Input
J/K/PT100
Recovery Time
2 sec minimum
Ambient temperature
Operation    :      +50 C to + 450 C
Storage       :      -100C to + 850 C
Variation due to temperature
0.250 C per degree change in ambient temperature (ref 250 C)
Humidity
Up to 85% RH @ 400 C
Insulation resistance
>100M ohms @ 500V DC
Service life(under no load)
106 operations minimum.
Electrical life (under full load)
105 operations minimum.
Dielectric strength
a)2.5KV AC, 50Hz for 1 minute. (Between current carrying & non-current carrying parts)
b)1.5KV AC, 50Hz for 1 minute. (Between contacts & control circuit)
c)750V AC, 50Hz for 1 Minute. (Between non-continuous relay contacts)
Electrical Connection
Screw type terminals with self lifiting clamps.
Dimension
72X72X128.5 mm (WXHXD)
Enclosure(Series)
C Series.
ISSUE DATE:16/10/07