MODEL:C3PT-MD |
|||||||||||||
| Function | |||||||||||||
| Function | ON DELAY / INTERVAL / CYCLIC (Down Counting) | ||||||||||||
| Voltage | |||||||||||||
| Rated Supply Voltage | 85V to 270V AC/DC | ||||||||||||
| Operating Voltage Range | (Not Applicable). | ||||||||||||
| Allowable Ripple | (Not Applicable). | ||||||||||||
| Time Range | |||||||||||||
| Time Range | 0.10 Sec to 99Hrs 59 Min | ||||||||||||
| Range Selection |
|
||||||||||||
| Variation due to temp change | ± 2% max ± 100mSec | ||||||||||||
| Variation due to voltage change | ± 1% max ± 100mSec | ||||||||||||
| Variation due to freq change | ± 1% max ± 100mSec | ||||||||||||
| Setting accuracy | ± 1% ± 50mSec | ||||||||||||
| Repeat accuracy | ± 0.05% max ± 50mSec | ||||||||||||
| Recovery Time | 2 Sec minimum | ||||||||||||
| Start & Reset signal | 250mSec minimum (Potential free) | ||||||||||||
| Temperature Coefficient | (Not Applicable). | ||||||||||||
| Min Energization Time | (Not Applicable). | ||||||||||||
| Relay Output | |||||||||||||
| Control Output |
|
||||||||||||
| No. of relays/Change over | (Not Applicable). | ||||||||||||
| Service Life (under no load) | 106 operations minimum | ||||||||||||
| Electrical Life (under full load) | 105 operations minimum | ||||||||||||
| Rated frequency of opeartion | 1800 ± 5% operations per hour max | ||||||||||||
| Insulation resistance | >100M ohms @ 500V DC | ||||||||||||
| Electrical | |||||||||||||
| Power consumption | AC Aprox. 4VA / 1W | ||||||||||||
| Rated Frequency | 50/60 Hz ± 5% for AC only | ||||||||||||
| Electrical Connection | Screw type terminals with self lifting clamps. | ||||||||||||
| Ambient temperature | Operation : -100 C to + 550 C Storage : -250C to + 800 C |
||||||||||||
| Humidity | Max 85% RH @ 400 C | ||||||||||||
| Dielectric strength | a)2.5KV AC, 50HZ for 1 minute. (Between current carrying & non-current carrying parts) b)1.5KV AC, 50HZ for 1 minute. (Between contacts & control circuit) c)750V AC, 50HZ for 1 Minute. (Between non-continuous contacts of the relay) |
||||||||||||
| Physical | |||||||||||||
| Display | 4 digit 7 segment LED 0.56" | ||||||||||||
| Dimension | 72 X 72 X 128.5 mm (W X H X D) | ||||||||||||
| Panel cutout | 68mm sq | ||||||||||||
| Enclosure (series) | C1D series | ||||||||||||