| Model : PT-01 |
| Operating
Voltage Range |
- 20% to + 10% of rated voltage |
| Rated
Frequency |
50 Hz ± 5% |
| Control
Output |
1 c/o C & NO rated for 28A @ 250V AC,resistive load |
| Setting
Accuracy |
±10%max. w.r.t full scale ±100mSec |
| Repeat
Accuracy |
±1% max. ±100mSec |
| Recovery
Time |
100msecs minimum |
| Variation
due to voltage change |
±2%max ±100mS |
| Variation
due to temp.change |
±5%max. ±100mSec |
| Variation
due to frequency change |
±2%max ±100mS |
| Ambient
temperature |
Operating: - 10° C to + 55° C
Storage : - 25° C to + 85° C |
| Humidity |
Max. 85% RH @ 40° |
| Electrical
Life |
104 operations minimum(under full load) |
| Connections |
Screw type terminals |
| Dimensions |
196 X 90 X 150[L X B X H] |
| Power
Consumption |
AC approx. 25VA / 5W |
| Insulation
Resistance |
>100M ohms @ 500 V DC |
| Descriptive Strength |
a) 2.5 KB AC,50Hz for 1 min(between current carrying and non-current carrying parts) |