| Model : H4DT-10 |
| Function |
ON Delay Timer |
| Rated supply Voltage |
24V to 240V AC & 24V to 220V DC |
| Operating
Voltage Range |
- 10% to + 10% of rated voltage |
| Rated
Frequency |
50 Hz ±5% |
| Control
Output |
2 c/o rated for 5A@ 250V AC/28V DC, resistive load |
| Setting
Accuracy |
± 10% max.w.r.t. full Scale ±100 msecs |
| Repeat
Accuracy |
± 1% maximum ±100 msecs |
| Recovery
Time |
100 msecs. minimum |
| Rated
Frequency of operation |
1800 ±5%operations per hour max. |
| Variation
due to voltage change |
±2% max.±100 msecs |
| Variation
due to temp.change |
±5% max.±100 msecs |
| Variation
due to frequency change |
±2% max.±100 msecs |
| Ambient
temperature |
Operating: - 10° C to + 55° C
Storage : - 25° C to + 80° C |
| Humidity |
Max. 85% RH @ 40° C |
| Service
Life |
106 operations minimum(under no load) |
| Electrical
Life |
105 operations minimum(under full load) |
| Insulation resistance |
>100M ohms @ 500VDC |
| Connections |
8 pin plug-in-type |
| Enclosure(series) |
H1D Series |
| Electrical Connection |
8 pin plug -in-type |
| Dimensions |
48 x 48x 94mm [W x H x D] |
| Power
Consumption |
AC approx 3VA/1W DC Approx 2W |
| Panel
cutout |
45mm X 45mm |
| Insulation
Resistance |
>100M ohms @ 500V DC |
| Dielectric Strength |
01)2.5KV AC,50Hz for 1 Minute(between current carrying & non-current carrying parts)
02)1.5KV AC,50Hz for 1 Minute.(between contacts & control circuit)
03)1KV AC,50Hz for 1 Minute.(between non-continuous relay contacts) |